Technical product specification standards specify the following conventions when dimensioning drawings. ( 3. &. Dimensions should be read across the sheet and are usually placed at the bottom; vertical dimensions must be readable from the right-hand edge. Notes and dimensions should not be placed in a haphazard manner merely to fill gaps; they must be done in a methodical way and with due thought given to their placement and extent. There are usually three dimension lines: the line closest to the building should describe its small elements - for example, piers, door widths, and window openings; the second line should carry some of the small dimensions and reflect major features such as a wing, section or offset; the third line (farthest from the building line) should be an overall dimension that will show the total distance from outside face to outside face of the building. 2. Dimensioning of architectural drawings involves actual sizes, regardless of the scale employed. OJ QJ 5�CJ OJ QJ CJ OJ QJ OJ QJ j OJ QJ U j"E U"j��= They may also show specific locations or references. 2. Similar dimensions or the same dimensions may be required several times on different drawings. 1. The ability to dimension properly requires the following: 1. Standard Practices- Reading Direction All dimension and note text must be oriented to be read from the bottom of the drawing (relative to the drawing format). $ �E��̛π~3z��/�%���n|�� �ΫbE�� Items are often referenced one to another. All drawings should agree - most of all with the specifications. A typical dimensioned drawing is shown below. When … ANSI Y14.5M-1994 is the current standard. EMBED AutoCAD.Drawing.15
14. Other standards may apply. The draftsperson must decide whether to use 12 inches or the symbols for feet and inches (12� or 1�-0�). The … Dimensions… OJ QJ UVhmH nH "j��= Dimensions are used to manufacture parts and to inspect the resulting parts to determine if they are acceptable. 12. Extension lines should be started 1/16" from the object , and extend beyond the dimension line by 1/8". It is a good idea to group notes around the construction to which they refer. OJ QJ UVhmH nH j U>*5� 0 � � " � � H � L � direct dowload for pdf not working problem. Dimensions:
The purpose of dimensioning is to define size and location of the various materials and components. AutoCAD Architectural Dimensioning CAD Fundamentals I
CAD Fundamentals I Architectural Dimensioning AutoCAD
Information Architectural Dimensioning CAD Fundamentals I
Construction Drawings ARCH 411
� � � � � Notes should always be concisely phrased to make a point that could be difficult and cumbersome to display in a drawing. What appears on the plans should appear on the elevations, wall sections, and so on. ���X�����9%�]_]��0:H��5���fڥ�����G�:�^��V5��s_�ێ��t�'�?�����6u�K_�YmE��u��%\���XA/���ͭ?0�^�/%�j��z� }�N�ƈ�����kCO:ii�ϓ��W��`���`i
%U�Q�6I��ef��㸖p�
;U�All{����.G�!��UHOt`���@z�:�sb��o�K�P&�RS��I!�4c�*��V
�P������7{~{"��]�w3�(�쒠(1�Ҍq���s�� vqmnu��k�����3M���>��ؾ>Bݟ2���L�t
�wlUklhr���
���:�'�?���A;��1�}�x�m �u�4/4�Ϊ��D3��x�`�B��g�8�bp���6 Academia.edu is a platform for academics to share research papers. This will eliminate the need to repeat each unit from start to finish of the series. The following list of architectural dimensioning standards is taken from “Architectural Working Drawings”, by Ralph W. Liebing and Mini Ford Paul (Wiley - Interscience, 1983). The first dimension lines should be spaced 3/8" or 10 mm from the object, and 1/4" or 6 mm away from each adjacent dimension . Leader lines should point away from the first or last line of a given note, never from the center, and should connect with the material to which it refers. � � E e � � � � � � � � � � � � � � � � � � � � � � � � � � � � �� � 2. Dimensions, Notes and Titles
Dimensions, notes and titles contribute a great deal to the complexity of a drawing. ��ض�?g�}]@�[���c�ˀ����z:k;�9F��Z���\�ڈz��a���0����������ᘤب�Iۄ��ˡc�-�ث�I���5_0���[��h�L����`ׁ9fq_:����X����V�COgx�����o�n�~�� �������K@�ͳ���
5S�&��V� k��F���=��k=� �6jQK5��=dM"k������P�ZH�H�v�5�Pk�F��6�n�n��"i$�%i'�(i*�+h-�>��62�d���a)�uПt+�Mm�}�_Q_��!e�T"S�LI���!m�t��ߐ/�eI�2�R�en�X�i����.���2p�l��dXf��G.Kb�"}��ry�=�:ߗL��Kl_z�,�j��K�o g��E=���-����-�����H#��?/v�?��j#b�����S� A column, for instance, would have a centerline running in both directions. A A � � �� �� �� ] & & & & � � � � � � � 8 � � � � b " : \ \ \ \ � � � � � � � $ I � = R � � � � & & \ \ � " � � � L & R \ � \ � � � & & & & � � � � k V ` @ x " � � \ ��|X�� � k d � The following list of architectural dimensioning standards is taken from �Architectural Working Drawings�, by Ralph W. Liebing and Mini Ford Paul (Wiley - Interscience, 1983). To avoid needless dimensions or crowding, door and window sizes are often eliminated by the use of marks and a scheduling system; The contractor can then apply the correct size to any given location. Fractions should be shown with a diagonal slash by which the numbers are separated for greater clarity. Architectural Standard - Ernst & Peter Neufert - Architects' Data. Extension lines indicate the points between which the dimension figures apply. 2. A door place in a narrow hallway does not necessarily have to be dimensioned, the inference being that the door will be centered. This will result in an uncomplicated system of leader lines. Dimensions, Notes and Titles. A note may contradict the dimension given; for example, a 2x4 stud may show a measurement of one and one-half inches (1 ��) by three and one-half inches (3 ��). ��ࡱ� > �� ! # ���� P � O �������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� q � n bjbjt+t+ ). 4. The minimum should be a full line height or half the height of the lettering. 6. Notes should be as close to the point of application as possible; for example, the topmost note directed to the floor slab should describe the topmost material in the floor slab construction, and so on down the line.